Patchadd return codes cobol

If the cobol module sets the returncode special register, its value can be retrieved from the stub using the stub. So grab a book on cobol programming, if you need one, beginning cobol for programmers by michael coughlan is an excellent choice, and start exploring the world of cobol. Jobs dont stop because of condition codes, rc 12 could be a perfectly acceptable return code for another program. The mvs server returns a status of 00 when writing a record to an indexed file which results in two or more records with identical keys. If you have conditions for running steps, either cond or if, and the condition determines that a step is not run, then there is no return code from the step. Is it possible to add inline comments in cobol stack. File status code, return codes for data files and vsam.

Status code 92 when accessing vsam file dynamically ibm. Both ibm vs cobol ii batch processing and micro focus cobol return a status of 02 when such a condition arises. Cobol, display file status code the following member cblrtnc1. I get this return code immediately after calling the module i display return code as the first line in the subroutine. Can i know if there is any mistake in the sysin statements. Any code that starts with a 0 is considered successful. Display file status information, a suite of cobol programs. I want to add a line control feed line feed, special character code or something like thatat the end of each record in my output file. Here we have a list of return codes that you can expect to see when patching solaris servers. Returncode from oracle is unpredictable micro focus. Some cobol code double dash indicates comment to end of line then write a program that looks for the double dashes and have it delete the and the text. For a write or rewrite statement, the record just written created a duplicate key value for.

How do you set a return code to the jcl from a cobol. Immediate return code 255 when calling a module using visual cobol 2. Below, i take a look at three open source projects that help you code, compile, and use cobol on a mac, linux, or windows computer. If the return type of the main function is a type compatible with int, a return from the initial call to the main function is equivalent to calling the exit function with the value returned by the main function as its argument. The ansi74 and ansi85 file status conventions are augmented with extended file status codes. This section covers parameters, return codes and call conventions for mixed language development with native cobol. For example, my jcl is right when it return 16 as maxcc under condition of empty file. Unfortunately it is not a valid return code in common. A full list of microsoft cobol v2 file status codes is given in the chapter file status code tables. Extended file status codes have the character 9 as the first byte of the file status. Then in your compile jcl, input your source code to the program, and the output to the compiler. I am using micro focus cobol on windows system and have this code.

Any code that starts with a 1 is considered to be an at end condition. Im not sure what your return code is, hex or decimal, and you seem to have listed two, 56361008 and 08600048. If the cobol runtime system terminates due to an error, for example, program not found, rts 114, etc. The vsam status code contains meaningful values when the cobol file status key is not 0. I dont know cobol and ive never used bpxwdyn, but i believe for the most part it is a wrapper for dynalloc svc99. Immediate return code 255 when calling a module micro. The only reliable exit codes are 0 and 0 see the patchadd 1m man page and youll find the exit codes very rarely actually match this list unless you use the t option to patchadd. Run a program that has intermediate code which has been produced on a version of your cobol system that is incompatible with the runtime system you are using. If control returns to the operating system, the value of the returncode special register is passed to the operating system as a user return code. Reason codes that are set in the rpl indicate record management errors. This article addresses the unpredictability of the value in the returncode special register once cobol has called an oracle routine.

Cobol file status status description 00 successful completion 02 indexed files only. Now, the codes didnt change much over the years up until solaris 10, when patchadd went from a script to a binary, and then the first 33 or so stayed the same and they just added a. I want to set a return code to the maxcc before my jcl ends. Calling bpxwdyn through cobol and getting return code as. On a system with zones5 installed, a return code of 0. What this means is that if you have a cobol program that calls. You can define dataname8 in the workingstorage section, as in vsamcode below. If the cobol module does not set the returncode special register, then the getreturncode method always returns 0. For the cobol environment if the file status clause is specified in the filecontrol entry, a value is placed in the specified status key the 2character data item named in the. The complete cobol course from beginner to expert 4. If a returncode in the cobol pgm can full ur requirement, returncode is a key var just like. Hi, i have a code like this, workingstorage section. Maintains the patchadd return codes from the solaris release prior to solaris 10.

The data item dataname8 specifies the vsam status code, which you define as a 6byte alphanumeric group data item that has three subordinate 2byte binary fields. This is the code for reading and extracting data a3 file. As has been discussed in this ng before, there are some products such as db2 and even infrequently cics that are not nice about clearing r15 all the time. The step is not run, it is flushed, so there is no rc. If control returns to the operating system, the value of the returncode special register is passed to the operating system as a. Return codes superc displays the completion message at the top of the primary comparison menu or at the top of the primary search menu. Vsam return code 44 received on write to fixed length file showing 19 of 9 messages. Im trying to compile a cobol program with the dfhyitvl jcl but at the end i recieve a mesage that say return code 8, the object program is generated but i can not execute it because the cemt instruction fail in the last step cemt s progname load failed. Your runtime system, therefore, cannot execute correctly any generated code you are producing or have already produced from this intermediate code. Embedded html embedded html ehtml enables you to output html directly from a cobol cgi program. Any code starting with a 2 is considered to be an invalid key condition. Just one other warning about rc return code and cobol. In an application that uses procobol, cobol passes control to oracle routines for example, during a sql connect, after which the flow of control returns to cobol.

How do you set a return code to the jcl from a cobol program. The symbolic key is moved into the data fields within the record in program variable storage. It compiles with no errors but when i run it i get a u4038 abend. My habit with vsam is to use the second cobol file status variable to get the actual vsam return and reason codes. This file has multiple occurences of account numbers but the code is not reading all occurences and gives file status 92.

I am trying to execute a simple cobol program on zos mainframe system. These return codes are paired with reason codes that are set in the access method control block acb and the request parameter list rpl. The returncode special register can be used to pass a return code to the calling program or operating system when the current cobol program ends. If the cobol module does not set the returncode special register, then the getreturncode method always returns. Program has taken more cpu time than the default limit for the job class could indicate an infinite loop. The message is an interpretation of the following return codes. Table of codes regardless of which set of status codes is being used. If the runtime system terminates because the program terminates stop run or toplevel goback, the value of the returncode special register is returned. This document provides a summary of the twobyte file status code sometimes referred to as file return code or file status key with a brief narrative for each code. When using ansi74 or ansi85 file status codes, the runtime system returns extended status codes if the extended file status is more specific than what would normally be returned.

S222 the job was cancelled by subsystem or operator because it violated some restriction. When using ansi74 or ansi85 file status codes, the run. Cics questions and answers,jcl abends, jcl abend codes, cobol abends, cics abends, db2 sql codes, cobol file status codes, vsam file status codes, cobol tutorials, jcl tutorials, db2 tutorials, cics tutorials. Reason codes that are set in the acb indicate open or close errors. If the rest of the steps in your job are expecting to run on a rc0, then you will have to change something. After that if i try to read data from the file it gives status code 46. Second declaration is for defining a null indicator. For a write or rewrite statement, the record just written created a duplicate key value for at.

Its similar to the solaris 89 patchset installation codes, but there are. So, rather than return a generic file status, this cobol system returns an extended file status of 9007. Abend codes mainframe tutorials, cobol db2 jcl cics. Vsam return code 44 received on write to fixed length file.

338 1226 557 1164 1501 690 5 777 604 689 518 1391 1383 332 500 918 671 861 75 92 702 386 127 1604 1563 1441 1057 30 606 343 1062 590 1494 1274 784 1485 543 1371